@ManAnimal I worked with some fault simulating panels

2019-08-08 17:13:59 UTC  

nioc. PLC based?

2019-08-08 17:14:13 UTC  

The UK isn’t communist

2019-08-08 17:14:16 UTC  

No just hard wired

2019-08-08 17:14:17 UTC  

Wtf

2019-08-08 17:14:22 UTC  

It is now

2019-08-08 17:14:27 UTC  

vote jeremy corbyn

2019-08-08 17:14:28 UTC  

They each had 6 switches that simulated a fault

2019-08-08 17:14:29 UTC  

comrade

2019-08-08 17:14:35 UTC  

new venezula

2019-08-08 17:14:44 UTC  

Nothing wrong with a bit of communism

2019-08-08 17:14:49 UTC  

Or a bit of Socialism here and there

2019-08-08 17:14:58 UTC  

any interesting/mind numbing problems?

2019-08-08 17:15:08 UTC  

and then overthrowing of the rich

2019-08-08 17:15:11 UTC  

and eating them

2019-08-08 17:15:15 UTC  

The most complex one to diagnose was a faulty wire that caysed the two phases to connect in series through the components @ManAnimal

2019-08-08 17:15:17 UTC  

just bit communist

2019-08-08 17:15:28 UTC  

https://cdn.discordapp.com/attachments/598761542200197120/609072191224414220/1565284352867.png

2019-08-08 17:15:31 UTC  

Which caused the indicator lamp to act as a latch

2019-08-08 17:15:39 UTC  

The off button to do nothing

2019-08-08 17:15:48 UTC  

And the on button to turn off the lamp while held down

2019-08-08 17:15:58 UTC  

ew... fault through equip is bad joo joo...

2019-08-08 17:16:09 UTC  

It simulated a cut wire

2019-08-08 17:16:25 UTC  

But it caused something similar to if the neutral wire of a house was cut

2019-08-08 17:16:32 UTC  

Just all sorts of wacky behavior

2019-08-08 17:16:33 UTC  

I can’t wait until we ration

2019-08-08 17:16:38 UTC  

Amazing stuff

2019-08-08 17:16:39 UTC  

did it? cut wire at what current rating?

2019-08-08 17:16:47 UTC  

The professor had to give us a hint with the neutral wire analogy

2019-08-08 17:16:56 UTC  

https://cdn.discordapp.com/attachments/598761542200197120/609072559761260554/1565275626337.png

2019-08-08 17:17:00 UTC  

When I figured it out I slammed the desk with my eureka moment

2019-08-08 17:17:13 UTC  

ah, guess you are only dealing with WYE connections

2019-08-08 17:17:21 UTC  

Triphase

2019-08-08 17:17:24 UTC  

220

2019-08-08 17:17:30 UTC  

220v triphase thing

2019-08-08 17:17:32 UTC  

I DEMAND A 2ND REFERDUM

2019-08-08 17:17:36 UTC  

Fault in the control circuit

2019-08-08 17:17:37 UTC  

220 Delta vs 220 Wye

2019-08-08 17:17:59 UTC  

It was a motor starter simulator

2019-08-08 17:18:00 UTC  

Both are triple phase