Message from @Lebens

Discord ID: 339907348392968212


2017-07-26 01:11:51 UTC  

I concur with greg 100%

2017-07-26 01:12:40 UTC  

@Izat - VA keep an eye out for broken tabs on outlets. They may be switched

2017-07-26 01:23:43 UTC  

As a rule of thumb on a 120v circuit a 100w is around 1a

2017-07-26 01:25:10 UTC  

And dimmer switches can only handle usually around 600w. So if you plan on dimming that area you may need to divide the load across two dimming switches

2017-07-26 03:11:34 UTC  

Good to know, luckily no dimmers here but I may do some on the main level eventually

2017-07-26 21:34:07 UTC  

Anyone ever make an alternator?

2017-07-26 21:34:51 UTC  

That is, convert physical energy into electrical?

2017-07-26 21:48:22 UTC  

It is not the easiest thing to do. You basically have a motor that is working backwards. You have to have quite a bit of copper windings inside the frame and you would have to spein it very quickly. If you had it attached to a bicycle or other of means it would not be so bad

2017-07-26 21:48:55 UTC  

Electric lady would not be that difficult to build the difficult part is when you have to do the spinning!

2017-07-26 21:49:20 UTC  

*electrically

2017-07-26 22:02:20 UTC  

Seen them on sail boats. Was also thinking sewing table pedal.

2017-07-26 22:10:39 UTC  

Yes you have to get the ratios in the windings right and then have a set RPM to keep the voltage at a set level. I'm sure there are simple units I'm talking more along the lines of a consistent voltage output of 110v or higher

2017-07-26 22:11:52 UTC  

Any way to do it without copper? Practically I mean.

2017-07-26 22:15:34 UTC  

The two components of a motor or generator do not actually touch. It works off what is called induction. Copper or gold would give the best results. Some type of metal has to be used other metals do not work as well

2017-07-26 22:18:58 UTC  

Yeah is it basically a spinning core inside of coils?

2017-07-26 22:27:37 UTC  

Rotor and stator

2017-07-26 22:30:12 UTC  

Yes sir and giving what you're trying to do using steel or something of that nature just wouldn't work for the induction

2017-07-26 22:30:18 UTC  

Keep in mind when building this that it will always take more energy to make energy than the energy produced. Heat and friction are energy losses

2017-07-26 22:30:37 UTC  

^^^

2017-07-26 22:31:18 UTC  

This is the equation that prevents perpetual motion

2017-07-26 23:10:27 UTC  

Ugh im at a negro house giving an estimate

2017-07-26 23:10:55 UTC  

Literally a chimp out on tv..... and the smell....

2017-07-26 23:11:17 UTC  

slave art?

https://cdn.discordapp.com/attachments/322712495108128779/339907561593503744/20170726_160716.jpg

2017-07-27 00:04:58 UTC  

Hahaha

2017-07-31 13:36:07 UTC  

@Lebens What is a "R&R commercial 225A single phase panel?"

2017-07-31 17:16:04 UTC  

Remove and replace a 225A single phase panel

2017-07-31 17:38:44 UTC  

Ah ty

2017-08-01 02:07:28 UTC  

@Lebens so you basically disconnected all the wires from the old panel, tracked them, and required them to the new panel?

2017-08-01 02:08:00 UTC  

How long does that take?

2017-08-01 02:08:38 UTC  

Im on my 10th hour

2017-08-01 02:08:53 UTC  

Still not done

2017-08-01 02:09:04 UTC  

Tomorrow i have another one to do

2017-08-01 02:09:08 UTC  

Holy feck

2017-08-01 02:09:22 UTC  

Wednesday im installing a lighting control system

2017-08-01 02:09:49 UTC  

2.5 days work and ill clear $6k

2017-08-01 02:10:09 UTC  

Contractor life

2017-08-01 02:11:02 UTC  

That's awesome.

2017-08-01 02:22:48 UTC  

@Lebens that panel/meter combo in that last picture is the second one of those I've seen you post. It's similar to what I would call a meter bank for a multi dwelling bldg. Is that something that is common for your area. Is that what the utility requires? I'm in Louisville and all of the services that we install have a meter Base outside and then a panel beneath it or just inside the wall from it. I was just wondering if that is something that you personally prefer or is that something that is common to your neck of the woods

2017-08-01 02:36:42 UTC  

@Deleted User east coast vs west coast. Out here we use all in one enclosures, i hate it. You guys have the better version

2017-08-01 02:39:29 UTC  

@Deleted User this building wanted a way to work on the panel without shutting down the substation also. With the meter socket they can monitor usage and have a means of disconnect for swapping main breaker

2017-08-07 18:38:14 UTC  

I was getting ready to run an outlet off this existing outlet. First tree ground wasn't connected and three was a jumper you can see in the pic. It's this normal practice. I've never seen it before.

https://cdn.discordapp.com/attachments/322712495108128779/344187498165043201/20170807_133608.jpg